Expand and Collapse Menu
 

    Industrial Statistics - Status of CREP Industries in Kalyan

 
 
NAME OF REGION :- KALYAN
Industries Established on of before Decemeber 31, 1991

Sr.

No.

Name & address of Industries with contact Numbers/E- mail I D
Category (R/O/G)
Type (L/M/S)
ISO- 14001 certification
industrial effluent Quantity M3/Day
ETP units provided Emission control units provided HW Management provisions Status of ETP units status of emission control units Status of HWM provision units
Last date of inspection of ( 2003-2004)
Remarks
1
Ajanta Paper & General Products Pvt Ltd.,Wadavali, Kalyan Tel No. 95251 - 2271481, 2271482.
R
M
No
950
Krofta (Fiber rocovery plant) Clarifier, Aerator logoon, Sedimentation tank. Dust collector provided to Coal Fired Bolier.   All units of ETP are in operation Dust collector in operation. ---
7/31/2004
 
2
Auctel Product A-85,86 & C-22, Ph-I, MIDC,Dombivali Tal No. 95251 - 2470356, 2471248
R
M
No
83
Collection tank, Neutralization tank, Clarifalculator, Bio-reactor, Secondary Clarifier & SDB, CETP Member Scrubber provided for So2, NH3 1) Industry is a member of TTC. All units of ETP are in operation. Scrubber is in operation.  
3/0804
 
3
B. K. Industry Pvt Mohane, Ambivli, Kalyan
           
Closed since last more than 2 Years.
4
Balkrishan Industries Ltd., Ambivali Tal No.95251 - 2270701, 2270702 / 03
R
L
No.
2750
2 No. of Krofta, (fiber recovery plant) Clarifier,Sludge press , SDB, Dust collector provided to Coal Fired Bolier. 1) Industry is a member of CHWTSDF, Taloja All units of ETP are in operation. Dust collector in operation.  
7/31/2004
 
5
Century Chemical Ltd., Vill. : Shahad Tal :Kalyan
R
L
NO
100
Collection tank, Neutralisation tank, Clarifier, Final Storage tank & recycle in process Scrubber provided to Cl2, HCL. Industry is a Member of CHWTSDF, Taloja All units of ETP are in operation. All scrubber are in operation. 1) Industry is sending HW to CHWTSDF, Taloja.
6/30/2004
 
6
Dharamsi Morarji Chemical Co. Ltd. M. G. Road, Ambernath 2682241 to 45
R
L
No
360
Primary Air Pollution Control System provided Member of CHWTSDF In Operation In Operation Member of CHWTSDF
9/15/2004
 
7
Gharda Chemicals Phase-I, Dombivali Tel No. 95251- 2434835, 6/ 7
R
L
No
405
ETP comprises, Oil Separaters, Collection cum Netralsation tank, Bio-logical reactor, Primary clairflocculator, Secondary Clairifier, SDB, Sand bed filter, Fenton's reactor, Scrubber provided for So2, HCL, NH3 & Chlorine. 1) Industry has provided Incinerator for burning of Organic liquid waste & Distillation readuce.2) They are also sending HW to their own unit at Lote Persuram.3) Industry is a member of CHWTSDF, Taloja. All units of ETP are in operation. All scrubber are in operation. 1) Incinerator in operation. 2) Industry is sending HW to CHWTSDF, Taloja & Lote Persuram..
8/25/2004
 
8
Godhanwani Brothers P No 3, Saravali, Bhiwandi
           
Closed since last more than 2 Years.
9
Indian Dyestuff Inds (IDI) Near Shahad Railway St. P B. No. 227, Kalyan
R
L
No
16199
Primary Secondary Air Pollution Control System provided -- -- -- --
--
Unit Closed Since Oct 2000
10
Laxmi Board & Paper Board Mill, Plot No.2, Saravali, Bhiwandi
R
L
No
1500
Collection tank, Primary Clarifier, Arreation Tank, Secondary Clarifier, Sludge press. Dust collector provided to Coal fired Bolier. 1) Industry is a member of CHWTSDF, Taloja. All units of ETP are in operation. Dust collector in operation.  
7/2/2004
 
11
N.R.C. Ltd., Vill: Mohane, Kalyan Tel No. 95251 - 2270312/ 131415.
R
L
No
47500
I) For Ray on Zinc bearing Waste-units comprinsing of lime slurry preparation tank (4) Equalization tank (2) with compresior Air blowing each with capacity of 850M3 clari flocculator and SDB (6) the launder overflow meets common basin with on line pH. correction facility, than disposed off from the premises through a closed pipe line of 2 1/2 feet dia finding its way to Kalu esturian waters after the distance of 100 mtrs (Approx) II) The remaining factory Effluent of Rayon plant also meets the common basin with on line pH correction. III) The industrial effluent from chemical complex i.e. from CS2, H2 SO4, and HCL Plant is also received in common basin with the facility of on line pH correction by lime solution. IV) The domestic effluent of factory and colony is connected to Septic tank, and the over flow is pumped to a Collection tank followed by lagoon(Aerated) with 6 No's of surface Aerators. Thus treated Domestic waste is reused for gardening & Plantation to the extent of 50% & remaining is meets to common basin followed by common disposal pipe of factory, towards esturian waters of Kalu. Scrubber provide to So2, Cl2, H2S, CS2 Industry is a Member of CHWTSDF, Taloja All units of ETP are in operation. All scrubber are in operation. 1) Industry is sending HW to CHWTSDF, Taloja.
8/30/2004
 
10
Laxmi Board & Paper Board Mill, Plot No.2, Saravali, Bhiwandi
R
L
No
1500
Collection tank, Primary Clarifier, Arreation Tank, Secondary Clarifier, Sludge press. Dust collector provided to Coal fired Bolier. 1) Industry is a member of CHWTSDF, Taloja. All units of ETP are in operation. Dust collector in operation.  
7/2/2004
 
11
N.R.C. Ltd., Vill: Mohane, Kalyan Tel No. 95251 - 2270312/ 131415.
R
L
No
47500
I) For Ray on Zinc bearing Waste-units comprinsing of lime slurry preparation tank (4) Equalization tank (2) with compresior Air blowing each with capacity of 850M3 clari flocculator and SDB (6) the launder overflow meets common basin with on line pH. correction facility, than disposed off from the premises through a closed pipe line of 2 1/2 feet dia finding its way to Kalu esturian waters after the distance of 100 mtrs (Approx) II) The remaining factory Effluent of Rayon plant also meets the common basin with on line pH correction.III) The industrial effluent from chemical complex i.e. from CS2, H2 SO4, and HCL Plant is also received in common basin with the facility of on line pH correction by lime solution. IV) The domestic effluent of factory and colony is connected to Septic tank, and the over flow is pumped to a Collection tank followed by lagoon(Aerated) with 6 No's of surface Aerators. Thus treated Domestic waste is reused for gardening & Plantation to the extent of 50% & remaining is meets to common basin followed by common disposal pipe of factory, towards esturian waters of Kalu. Scrubber provide to So2, Cl2, H2S, CS2 Industry is a Member of CHWTSDF, Taloja All units of ETP are in operation. All scrubber are in operation. 1) Industry is sending HW to CHWTSDF, Taloja.
8/30/2004
 
12
Orex Pharma Pvt Ltd.,Plot No. B-5, Ph-I, Midc,Dombivali. Tel No. 95251- 2470711, 2471039.
R
M
NO
4
Collection cum Neutralisation tank, Settling tank, SDB.and Filters, CETP Member Scrubber is provided 1) Industry is a member of TTC ETP is in operation Scrubber is in operation.  
 
13
Sekhasaria Chemical 21/22, Phase - II, Dombivali Tel No. 95251- 871953.
R
M
No
80
Oil & Grease trap, Neutralisation tank, Bio-logical Oxidation,Primary & Secondary Settling tank, Filter Press, SDB. Scrubber provided to So2 & NOx 1) Industry is a member of CHWTSDF, Taloja All units of ETP are in operation. All scrubber are in operation. 1) Industry is sending HW to CHWTSDF, Taloja.
8/3/2004
 
14
Solid Container Vadavali, Mohane, Kalyan
           
Closed since last more than 2 Years.
15
Transchem Ltd. Plot No. 7, MIDC, Engg. Zone, K. B. Rd, Ambernath
R
M
No
143
Primary, Secondary, Tertiary Air Pollution Control System provided Member of CHWTSDF In Operation In Operation Member of CHWTSDF
9/2/2004
 
16
M/s. Bharat Fertilizer Ind. Ltd Sr.No. 114 115/3 227 part , 291 /1 ,291/2,346 Vill : Kharivali , Tal : Wada , Dist: Thane Phone : 02526 - 34427
R
M
--
80
Collection tank , Neu. Tank . Settling Tank , Solar Evaporation ponds. Disposed on land for irrigation Scrubber to fluorine recovery plant , Tailend gas scrubber to Sulfuric acid plant and Dust collector to SSP Plant provided Nil presently No. mfg. Activity presently No. mfg. Activity presently No. mfg. Activity
7/7/2004
Industry is closed since last one year
 
Industries Established on or after January 01, 1992

Sr.

No.

Name & address of Industries with contact Numbers E-Mail ID
Category R/O/G
Type L/M/S
ISO-1400 1 certification
Industrial effluent Qty. M3/day
ETP units provided Emission control units provided HW management provisions Status of ETP units Status of emission control units Status of HWM provision units
Last date of inspection of (2003-2004)
Remarks
1
M/s. SBL Colour Tech Pvt. Ltd., C-4, MIDC, Badlapur.
R
S
No
35
Primary treatment provided. CETP Member   Member of CHWTSDF In operation In operation Member of CHWTSDF
 
2
M/s. Metropolitian Exim chem. Ltd., Plot No. B-CFC, Phase-II, MIDC Dombivli, Tel. No. 95251-870975, 870808
R
M
No
200
1) For week effluent stream, collection cum neutralization tank, settling tank, SDB.2) For concentrated effluent stream. Incinerator provided. Scrubber provided to SO2 & Nox Industry is a member of CHWTSDF, TTC. All units of ETP are in operation. Air pollution control equipments are in operation. Industry is sending HW to CHWTSDF, TTC.
7/31/2004
 
3
M/s. Meghdoot Chemical, Plot No. ¼, MIDC Sarvali, Tal. Bhiwandi.
O
M
No
5.5
Collection cum Neutralization tank, Settling tank, SDB, & Filters. Dust collector provided. Industry is a member of CHWTSDF, TTC. All units of ETP are in operation. Dust collectors are in operation  
9/23/2004
 
 
Go Top
  Copyright © 2009 All Rights Reserved. Photo Gallery| Events| Awareness| Weblinks| FAQ's| Contact Us| Disclaimer| Site Map 
Powered By:Omkar Multimedia Communication.
Maintained by:Environmental Information Centre, Maharashtra Pollution Control Board